Modeling and Analysis of Harmonic in the Mine Hoist Cnverter Based on Double Closed-Loop Control
Abstract
In the process of converter driving mine hoist, the output voltage waveform of the inverter is distorted. A novel feedback control method based on the filter inductor current inside loop and voltage is developed in this study. The transfer function model of the two closed-loop control is builded. Parameters of the PID controller are determined through theoretical calculation after analysis of the impact the controller parameters on system. The simulation results show that the output waveform is good and the THD(Total Harmonic Distortion) values is small.
Keywords
References
[1] B.X. Tian, H.Y.Su, J.Chu, “Tuning Method of PID Controller based on State Estimation”, CHINESE JOURNAL OF SCIENTIFIC INSTRUMENT, vol.21-5. 2000.pp.476-480.
[2] K. J. Astrom and Hagglund et al, “PID Controllers: Theory, Design, and Tuning. Instrument”. Society of America, 1995.
[3] L.H.Xie, Y.M.Su, “Digital Control of Sine Wave Inverter”. Power Electronics, vol.35-6.2001.pp.51-55,60.
[4] J. Tong, P.T.Feng, “An Improvement to Hysteretic Control of Current-controlled Voltage-source-inverter”. ELECTRIC DRIVE, vol.5.1997.pp.3-6.
[5] K.P. Gokkhale et al, “Deadbeat Microprocessor Control of PWM Inverter for Sinusoidal Output Waveform Synthesis”. IEEE Trans.on IA, vol. 23-5.1987.
[6] X.J.Dai, Q.Chao, “Current control of constant hysteresis band for single phase photovoltaic grid-connected inverter”. Power System Protection and Control, Vol.37-20. 2009.pp.12-17.
[7] J.Gao, H.Li, “Digital Control Technology for UPS Inverters”. Electrotechnical Journal, Vol. 12.2001.pp.6~9.
[8] C.Hua, “Two-level switching pattern deadbeat DSP controlled PWM Inverter”.IEEE Trans. Power Electr. Vol. 10-5.1995.pp.310-317.
[9] X.Z.Lai, C.Z.Pan, M.Wu, “Global robust control of a class of underactuated mechanical systems”. Control and Decision, Vol.24-7. 2009. pp. 1023-1027,1032.
[10] K.Zhang, B. Jiang, “Fault Diagnosis Observer-based Output Feedback Fault Tolerant Control Design”. Acta Automatica Sinica, Vol.36-2. 2010.pp.274-281.
[11] H. Yu, J.Xiong, K.Zhang, Y.B.Wang, “Research on Waveform Control Technique Based on Deadbeat Control Theory”. Telecom Power Technologies, Vol. 2-24.2007.pp.9-12.
[12] B. Qu, X.Y.Hong, Z.Y.Lu, “Application of Fuzzy Control Theory to Deadbeat Control Scheme in Three-phase Pulse Width Modulation Rectifier”. Proceedings of the CSEE, Vol.29-15. 2009. pp. 50-54.
[13] G.M. Li, Y.X.Dai, L.Q. Yi, “Deadbeat Control Technique in Inverter System for Digital UPS”. Control Engineering of China, Vol.16-2. 2009. pp. 159-160,
[14] D.Biel, E.Fossas, F.Guinfoan, “Application of sliding-mode control to the design of a buck-based sinusoidal gener-ator”. IEEE Trans.On Industrial Electronics, Vol. 48-3. 2001. pp. 563-571.
[15] W.Wei, S.H.Xu, X.C. Guo, “Method on hybrid sliding-mode variable structure control of induction motor”. Electric Machines and Control, Vol. 13-3. 2009. pp. 458-463.
[16] X.Z.Zhang, Y.N.Wang, “Sliding Mode Control with Parameters Direct Self-tuning for Electro-hydraulic Servo System”. China Mechanical Engineering, Vol. 20-11. 2009. pp. 1285-1289.
[17] Wang Haibo, Zhou Bo, Fang Sichen, “A PMSM Sliding Mode Control System Based on Exponential Reaching Law”. Transactions of China Electrotechnical Society, Vol.24-9.2009.pp.71-77.
Full Text: PDF